ET48300005 5U 18kW 48V 300A DC Telecom Power System with Six 3kW Rectifiers and Front Service Distribution The ET48300-005 is a 5U rack-mounted DC telecom power system developed for communication sites that need dependable -48V power, organized load distribution and battery backup in a compact ...

Ürün Detayları

Vurgulamak:

48V telecom power system with 300A

,

5U 18kW DC power system

,

telecom power system with rectifiers

Solar Array: 24 adet 580W güneş panelleri
Input Capacity: 1 × 63a/2p
Thd: Dirençli yükte < % 1,5
Dc Load Breakers: 30 Pozisyon
Efficiency: ≥% 90
Certifications: ISO9001, CE, RoHS
Package: Kartonlar
Poweroutput: 10kW - 100kW
Ac Frequency: 50Hz, 60Hz veya Son Senkronize
Load Protection: LLVD, BLVD
Protectionfeatures: Aşırı Gerilim, Aşırı Akım, Kısa Devre, Aşırı Sıcaklık
Dc Current Max: 53,5 VDC / 43 - 58 VDC
Dc Output Breakers: 4
Frequency: 45 ¢ 66 Hz
Industrial Ac Input: Her bir rektifer için tek faz
Ürün Açıklaması

 

ET48300005 5U 18kW 48V 300A DC Telecom Power System with Six 3kW Rectifiers and Front Service Distribution

 
 
The ET48300-005 is a 5U rack-mounted DC telecom power system developed for communication sites that need dependable -48V power, organized load distribution and battery backup in a compact cabinet space. It is positioned as an 18kW / 300A class solution, using six 3kW rectifier modules to provide stable DC output for transmission equipment, access devices, switches and base-station loads.
 
This model is suitable for sites using 220VAC single-phase input, making it easier to deploy in equipment rooms or access network cabinets where three-phase power is not available. The system integrates AC input protection, AC surge protection, rectification, battery breakers, LLVD/BLVD load outputs, DC SPD, LCD monitoring and communication terminals into one front-service platform. The front panel layout allows technicians to check breaker status, controller alarms and wiring terminals without removing the system from the rack.

Product Features 18kW 48V 300A DC Telecom Power System

 

18kW modular capacity: Six 3kW rectifiers support flexible configuration and online maintenance.

 

300A DC output class: Suitable for medium to high-load telecom power distribution.

 

Single-phase AC input: Designed for 220VAC sites with 1 × 100A/2P input protection.

 

Clear load separation: LLVD and BLVD branches help divide priority and non-priority equipment.

 

Battery protection: Two 125A battery breakers support backup battery connection and isolation.

 

Surge protection: Integrated AC SPD and DC SPD improve system resistance to transient overvoltage.

 

Remote monitoring support: LCD controller with RS485, SNMP, dry contacts, AI/DI signal inputs.

 

Front maintenance design: Rectifier and controller are hot-pluggable for faster field replacement.

 

Application Scenarios 18kW 48V 300A DC Telecom Power System

 
The ET48300-005 is suitable for wireless base stations, transmission networks, fiber access sites, enterprise communication rooms, microwave stations, telecom cabinets and backup DC power systems requiring stable -48V distribution with battery management.
 

Technical Parameters 18kW 48V 300A DC Telecom Power System

 

Model: ET48300-005

 

Type: 3–18kW 5U Subrack

 

Maximum Current: 300A

 

Dimensions: 482.0(W) × 350.6(D) × 5U(H)

 

Weight: ≤22kg without rectifiers

 

Installation: 19-inch rack or cabinet

 

Cabling: Top inlet and top outlet

 

Protection Level: IP20

 

AC Input: 220VAC single phase

 

Input Capacity: 1 × 100A/2P

 

Frequency: 45–65Hz, rated 50/60Hz

 

AC SPD: 20kA/40kA, 8/20μs

 

DC Output: -43V to -58VDC, rated -53.5VDC

 

Maximum Capacity: 18kW, 6 × 3kW

 

Battery Breakers: 2 × 125A/1P

 

LLVD: 2 × 32A/1P + 2 × 40A/1P + 3 × 63A/1P

 

BLVD: 2 × 6A/1P + 2 × 10A/1P + 2 × 16A/1P

 

DC SPD: 10kA/20kA, 8/20μs

 

Rectifier Efficiency: >96%

 

Power Factor: ≥0.99

 

Operating Temperature: -40°C to +75°C

 

Humidity: 5%–95%, non-condensing

 

Altitude: 0–4000m

 

ET48300005 5U 18kW 48V 300A DC Telecom Power System with Six 3kW Rectifiers and Front Service Distribution 0

ET48300005 5U 18kW 48V 300A DC Telecom Power System with Six 3kW Rectifiers and Front Service Distribution 1

ET48300005 5U 18kW 48V 300A DC Telecom Power System with Six 3kW Rectifiers and Front Service Distribution 2

ET48300005 5U 18kW 48V 300A DC Telecom Power System with Six 3kW Rectifiers and Front Service Distribution 3

İLGİLİ ÜRÜNLER
  • 28U Düzeltme Sistemi ile Entegre Dış Güç Kabinesi UPS Pil enerji depolama kabı

    Düzeltme Sistemiyle 28U Entegre Dış Güç Kabinesi UPS Pil Enerji Depolama 1Kısa bir tanıtım: Açık hava telekom dolapları genellikle telekom ekipmanlarının korunmasını ve işlevselliğini sağlamak için çeşitli özelliklere sahiptir. Hava Duruma Dayanıklı Tasarım: Açık hava dolapları, yağmur, kar, aşırı ...
  • Dış Mekan Güç Kabini, Su Sensörlü / Kapı Sensörlü Dış Mekan Telekom Kabini

    Dış Güç Kabini, Su Sensörlü Dış Mekan Telekom Kabini / Kapı Sensörü 1. Açıklama Dolap tek bölmeli dolaptır.Kabin soğutması, ekipmanların hizmet ömrünü çok daha uzun ve performanslarını daha istikrarlı hale getirmek için ekipmanların normal olarak sabit sıcaklık aralığında çalışmasını sağlamak için ...
  • Jeneratör Soketli Sıcaklık Kontrolü Dış Telekom Kabini IP55 Giriş Koruması

    Sıcaklık Kontrolü Dış Güç Kabini / Jeneratör Soketli Dış Telekom Kabini 1. Özellikler (1) Teknik Parametreler Giriş Koruması: IP55 B Sınıfı Yıldırım Geçirmez: Nominal: 60KA, Maks.: 100KA Sıcaklık: Çalışma Sıcaklığı: -40°C ~ +55°C Depolama Sıcaklığı: -50°C ~ + 70°C Taşıma Sıcaklığı: -50°C ~ +70°C Bağ...
  • Emerson Doğrultucu / Akü Dış Mekan Güç Kabini Sandviç Yapı Paneli IP55

    Emerson Doğrultucu ve Batarya ile Sandviç Yapı Paneli Dış Mekan Güç Kaynağı Kabini 1 Ürün Açıklaması 1.1 Dış görünüş Kabin montajı yapıldıktan sonra Şekil 1 ve Şekil 2'de gösterildiği gibi Şekil 1 Şekil 2 1.2 Kabin konfigürasyonu Bu projenin dış mekan entegre kabin konfigürasyonu aşağıdaki gibidir: ...

Soru Gönder